Corometrics 129 Fetal Monitor

Corometrics 129 Fetal Monitor

Brand:GE
Web ID:991
Condition:Refurbished

0item is in your cart.View cart now

Need help?

Get an Equipment Quote

(800) 462-8195

Biomedical HTM Customers

Service, Repair & Parts

(800) 449-5328

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Corometrics 129 Fetal Monitor is the top-of-the-line, fully featured fetal monitor of the Corometrics 120 Series. This comprehensive maternal/fetal monitor provides the ability to address every monitoring need for both the mother and the fetus.

Features

  • Maternal 3-lead ECG
  • Pacer Detection
  • Lead Selection
  • Display of Waveform
  • Integrated Maternal NIBP and MSpO2
  • Dual Ultrasound
  • 胎儿心电图
  • Uterine Activity

Specifications

Ultrasound Mode

  • Technique: pulse Doppler with autocorrelation processing.
  • Transducer type: 9-crystal.
  • Pulse reception frequency: 4 kHz single ultrasound mode, 2 kHz dual ultrasound mode
  • Pulse duration: 92 µs
  • Transmitter frequency: 1.151 MHz
  • Intensity: <5mW/cm2
  • Heart rate counting range: 50-210 BPM
  • Leakage current: <10 µA at 120-240 VAC, isolated by transducer

胎儿心电图Mode

  • Technique: peak detecting, beat-to-beat cardiotachometer.
  • Heart rate counting range: 30-240 BPM
  • Heart rate resolution: ±1BPM
  • Artifact elimination: switch selectable, ±25 BPM artifact rejection
  • Countable input signal range: 15 µV to 2mV peak-to-peak.
  • Offset voltage tolerance (differential): ±300 mVDC maximum
  • Maximum common mode voltage: 20V peak-to-peak
  • Preamplifier bandwidth: 1-100 Hz
  • Common mode rejection: balanced > 120 dB at mains frequency
  • Input equivalent noise: <10µV peak-to-peak
  • Input impedance: differential > 10 MΩ, common mode > 20 MΩ
  • Mains frequency rejection: > 40 dB
  • Leakage current: < 60µA at 254 VAC, electrically isolated
  • Isolation, mains-to-patient: >4kVAC
  • Leg plate tester jack: simulated r-wave at 120± 1 BPM

Fetal Alarms (for Ultrasound or FECG Modes)

  • Audio: alternating 1.5 second chimes (773 Hz and 523 Hz).
  • 视觉:心率numeri闪烁c
  • Limits: user selectable high and low fetal heart rate
  • Technical: signal quality
  • Tachycardia response time: 5 minutes at 100% limit violation
  • Bradycardia response time: 30 seconds at 100% limit violation
  • Signal quality response time: 100% signal loss - 1.25 minutes, 70% signal loss - 5 minutes, 65% signal loss - 10 minutes